Screen Printed Electrodes - with Polymer Base Types:Carbon Single Electrode 5mm diaGold Single Electrode 5mm diaCarbon 3 electrode : C 3mm dia / C / AgGold 3 electrode : Au 3mm dia / Au / AgGold 3 electrode : Au 3mm dia / Au / AgCl Catalogs:-Screen printed Electrode – Carbon Screen printed Electrode – Gold Flow Sensing Screen Printed Electrodes - with Ceramic Base Electrode material :PtAuCarbonAgAu/Pt Type:Single working electrodeThree electrodes Working – Counter – ReferenceMultiple Working electrodes AC1 AC2 AC3 AC4 Ac5 AC6 optional type AC8 AC9c Optional optional CC1 CC2 CC3 Optional Catalog:AC1 sensor – Basic amperometric low cost three-electrode sensor with patented structure made by thick film technology. MAC sensor – Microreactor for sensor used for measurement of small volume (20 µl) in closed system.AC1.AChE sensor – Amperometric Acetylcholinesterase three-electrode sensor with patented structure made by thick film technologyAC1.GOD sensor -Amperometric Glucose Oxidase three-electrode sensor with patented structure made by thick film technology.AC1P sensor – Amperometric three-electrode sensor with patented structure type AC1 with polished working electrode made by thick film technology.AC2 sensor – Amperometric two-electrode sensor with two working electrodes made by thick film technology.AC3 sensor – Narrow amperometric single working electrode sensor made by thick film technology.AC4 sensor – Amperometric single working electrode sensor with an extremely big working electrode made by thick film technology.AC5 sensor – Screen printed electrochemical array of 8 working electrodes.AC6 sensor – Amperometric three-electrode sensor with two auxiliary electrodes made by thick film technology.AC8 sensor – Amperometric sensor with 4 working electrodes made by thick film technology.AC9C sensor – Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode made by thick film technology with integrated connector.AC9C.WSP sensor – Amperometric sensor with an array of 8 working electrodes and 1 common reference electrode. This is a similar sensor design as AC9C, but the layers are applied by sputtering.CC1 sensor – A conductivity sensor made by thick film technology with interdigitated structure of electrode.CC2 sensor – A conductivity sensor with two active parts made by thick film technology with interdigitated structure of electrodes.CC3 sensor – A conductivity sensor made by thick film technology with interdigitated structure of electrodes.STK.RDE sensor – Set of twenty electrochemical sensors to start your measurement with miniRDE.FC2 Flow cell – Standard transparent PMMA flow cell enables the use of AC1 and CC1 sensors in a flow through arrangement.FC3 Flow cell – Transparent PMMA flow cell enables the use of AC1, AP1 and CC1 sensor together with illumination of the working electrode. The cell was designed for herbicide detection.FC4 Flow cell – High quality PEEK device with USB connection which enables the measurement at defined mass transfer towards electrode surface. The device enables measurement of small volume of sample.Manual Screen Printer – MSP – Under optimal conditions printing of lines with 200 µm can be achievedMini Rotating disk electrode – High quality PEEK device with USB connection which enables the measurement at defined mass transfer towards electrode surface. The device enables measurement of small volume of sampl Contact For any inquiries please email info@ipgi.co.in