Wireless Potentiostat : Single & Multichannel Type

Eis Potentiostat

Features : 

Wire less transmission : max 20meter

Multichannel : connect 1~8 channels at the same time & control simultaneously or individually

Electrochemical method : Setting simultaneously or individually with electrochemical methods

Electrochemical method :

  1. Cyclic voltammetry (CV)
  2. Amperometry ( IT)
  3. open circuit potential
  4. Differential pulse voltammetry (DPV)
  5. Square Wave voltammetry (SQW)
  6. linear Sweep Voltammetry (LSV)
  7. Pulsed Amperometry (Pulsed IT Curve)
  8. AC Impedance (EIS)
  9. Impedance – Time (IMPT)
  10. Impedance – Potential (IMPE)

Range :

  • Voltage scan  range: +1800mV ~ -1800mV
  • Current range : 1mA ~1000pA
  • EIS   0.2Hz – 200kHz

Single channel

Features : 

Wire less transmission : max 20meter

Multichannel : connect 1~8 channels at the same time & control simultaneously or individually

Electrochemical method : Setting simultaneously or individually with electrochemical methods

Present ON Mobile App :Electrochemical data can be transferred to phones App to simulate the application of sensor

Electrochemical method :

  1. Cyclic voltammetry (CV)
  2. Amperometry ( IT)
  3. open circuit potential
  4. Differential pulse voltammetry (DPV)
  5. Square Wave voltammetry (SQW)
  6. linear Sweep Voltammetry (LSV)

Range :

  • Voltage scan : +2 ~ -2V
  • Current range : 1mA ~100pA
  • current resolution : 0.5% of range
Multichannel

Features : 

Wire less transmission : max 20meter

Multichannel : connect 1~8 channels at the same time & control simultaneously or individually

Electrochemical method : Setting simultaneously or individually with electrochemical methods

Present ON Mobile App :Electrochemical data can be transferred to phones App to simulate the application of sensor

Electrochemical method :

  1. Cyclic voltammetry (CV)
  2. Amperometry ( IT)
  3. open circuit potential
  4. Differential pulse voltammetry (DPV)
  5. Square Wave voltammetry (SQW)
  6. linear Sweep Voltammetry (LSV)

Range :

  • Voltage scan : +2 ~ -2V
  • Current range : 1mA ~100pA
  • current resolution : 0.5% of range

Multi Channel Potentiostat

A) Multi-channels with individual control of 3 electrodes system.
(B)Multi-channels of electrochemical graphs (including CV,IT,OCP) showing simultaneously or individually.
(C)Execution of electrochemaical methods continuously and automatically.
(D)Save data automatically.
(E)Data Analysis automatically.

(A)Potential range: +2~-2V
(B)Measured current range : Amps 10-2~10-10 
(C)Channels:2~10

Resolution  :1.2 f A

Contact

For any inquiries please email